Method transfer FDA

A method transfer is the process of qualifying a laboratory regarding its ability to carry out an analytical test procedure. For method transfer, FDA has some regulations that are simple on the face of it, but require many steps and precautions. Not being in compliance with these steps could invite investigation and corrective measures to ensure that validated method transfer is carried out.

For a lab to meet method transfer FDA has set; it has to ensure that some pre-method transfer steps are adhered to. These include:

  • Unambiguous and clear communication between the sending and receiving lab on all the aspects of method transfer
  • Nomination of ideally a single person or point of contact between the sending and receiving labs, a person who will coordinate on the details of the transfer
  • Complete and clear assessment of the method of transfer
  • Identification of the required method transfer
  • Evaluation of issues arising out of the context of the location, such as data collection systems, instruments and reagents and coagulants.

Documents to be sent by the sending laboratory

To meet method transfer for FDA requirements, the pre-approved transfer protocol of the sending laboratory will typically consist of the following documents:

  • General transfer process
  • Definition of responsibilities of both parties
  • Specifics of the acceptance data
  • A list of the methods
  • Categorization of the methods
  • A description of samples and materials
  • Description of batch and lot records
  • Definition of parameters and instrumentations

Materials to be sent by the sending laboratory

Talking about the materials to be provided by the sending laboratory, these are usually part of method transfer the FDA requires:

  • Method, which consists of system suitability parameters, rationale for chosen, parameters, step-by-step directions and safety considerations
  • Validation report
  • Reference standards
  • Samples for evaluation, and
  • Supplies that are difficult to procure

Reference:

http://www.nbchem.de/mediapool/120/1202675/data/110914_AMDVT_bn.pdf

Contact Detail
GlobalCompliancePanel
webinars@globalcompliancepanel.com
http://www.globalcompliancepanel.com
Phone:800-447-9407
Fax:302-288-6884
43337 Livermore Common | Fremont| CA | USA | 94539

 

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s